BPZJJ - FUMING SUFURIC ACID, A-304

  • MSDS: BPZJJ
  • Manufacturer: FISHER SCIENTIFIC
  • Product Name: FUMING SUFURIC ACID, A-304
  • National Stock Number: 6810-00-975-1537
Product Identification

Product ID:FUMING SUFURIC ACID, A-304
MSDS Date:03/30/1989
FSC:6810
NIIN:00-975-1537
MSDS Number: BPZJJ

Responsible Party
FISHER SCIENTIFIC
1 REAGENT LANE
FAIR LAWN, NJ 07410
US

Emergency Phone: 201-796-7523;800-424-9300(CHEMTREC)

Info Phone: 201-796-7100

Cage: 1B464

Contractor
FISHER SCIENTIFIC CO. CHEMICAL MFG DIV
FAIRLAWN, NJ 07410-2802 US

Telephone: 201-796-7100

Cage: 1B464

Ingredients

SULFURIC ACID, FUMING; (FUMING SULFURIC ACID) PEL/TLV

CAS: 8014-95-7

RTECS: WS5605000

Fraction By Weight: 100%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3;3 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


BLOOD. ASPHY CAN OCCUR FROM SWELLING OF THROAT.

RTECS: 9999999ZZ


MIST CAUSES CHRONIC TRACHIOBRONCHITIS, EROSION &

RTECS: 9999999ZZ


STUDIES SUGGEST AN INCREASED RISK OF LARYNGEAL CANCER

RTECS: 9999999ZZ


RPTD/PRLNGD EXPOS TO LIQ/MIST MAY CAUSE IRRIT/DERM.

RTECS: 9999999ZZ


REMAINS (AT LEAST 15-20 MIN). IN CASE OF

RTECS: 9999999ZZ


SECURELY, BUT NOT TOO TIGHT. GET MD ATTN IMMED.

RTECS: 9999999ZZ


& LOWER LIDS, UNTIL NO EVID OF CHEM REMAINS (AT LEAST

RTECS: 9999999ZZ


UNTIL PH HAS RETURNED TO NORMAL (30-60 MIN). COVER

RTECS: 9999999ZZ


USE GASTRIC LAVAGE/EMESIS. DILUTE IMMED BY DRINKING

RTECS: 9999999ZZ


REPEATEDLY. INGESTED ACID MUST BE DILUTED APPROX 100

RTECS: 9999999ZZ


AIRWAY AND TREAT SHOCK. GET MD ATTEN IMMED. IF VOMIT

RTECS: 9999999ZZ


NO SPECIAL ANTIDOTE. TREAT SYMPTOMATICALLY

RTECS: 9999999ZZ


OF AN EXPERT. DIKE SPILL FOR LATER DISP. DO NOT

RTECS: 9999999ZZ


PEOPLE AWAY. ISOLATE HAZ AREA & DENY ENTRY. VENT

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:CORR/TOX. MAY CAUSE
NOSE/THROAT IRRIT, HDCH, COUGH, AN INCREASE IN RESP RATE/IMPAIRMENT
OF VENTILATORY CAPACITY. DELAYED SYMPT MAY INCLUDE PULM EDEMA,
TIGHTMESS IN CHEST, CYANOSIS, HYPOTEN SION, BRONCHITIS/EMPHYSEMA.
SKIN:CONTACT MAY CAUSE SEV IRRIT, PAIN, BURNS & VESICULATION. (EFTS
OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:EYE:DIRECT CONTACT W/CONCENTRATED ACID
SOLUTION MAY CAUSE SEV DMG, OFTEN LEADING TO BLINDNESS. DILUTE
SOLUTION PRODUCE MORE TRANSIENT EFTS FROM WHICH RECOVERY MAY BE
COMPLETE. EXPOS TO MIST M AY CAUSE IRRIT & LACRIMATION. INGEST:MAY
PRODUCE SERIOUS BURNS OF MOUTH & ESOPHAGUS. MAY BE PAIN IN ABDOMEN
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG HAS STOPPED, GIVE
ARTF RESP. MAINTAIN AIRWAY & BLOOD PRESS & ADMIN O*2 IF AVAIL. KEEP
AFFECTED INDIV WARM & AT REST. TREAT SYMPTOMATICALLY &
SUPPORTIVELY. ADM IN OF O*2 SHOULD BE PERFORMED BY QUALIFIED INDIV.
GET MD ATTN IMMED. SKIN:REMOVE CONTAM CLTHG/SHOES IMMED. WASH
AFFECTED AREA W/SOAP & MILD DETERGENT & LRG AMT OF WATER UNTIL NO
EVID OF CHEM (ING 6)

Fire Fighting

Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE OR HALON. (1987
EMERGENCY RESPONCE GUIDEBOOK, DOT P 5800.4).
Fire Fighting Procedures:LRG FIRES:FLOOD AREA W/WATER FROM A DISTANCE.
DO NOT GET SOLID STREAM OF WATER ON SPILLED MATLS. USE FLOOD FOG.
MOVE CONTR FROM FIRE AREA IF POSS. COOL (SUPDAT)
Unusual Fire/Explosion Hazard:VIOLENT EXOTHERMIC REACTION W/WATER &
ORGANIC MATERIALS. MAY IGNITE FINELY DIVIDED COMBUSTIBLE MATERIALS
ON CONTACT. NEGLIG HAZ WHEN EXPOS TO HEAT/FLAME.

Accidental Release

Spill Release Procedures:OCCUP SPILL:KEEP COMBUST AWAY FROM SPILLED
MATLS. DO NOT TOUCH SPILLED MATLS. DO NOT GET WATER INSIDE CONTR.
STOP LEAK IF CAN BE DONE W/NO RISK. USE WATER TO REDUCE VAP. DO NOT
PUT WATER ON LEAK/SPILL AREA, CLEAN UP ONLY UNDER SUPERVISION (ING
14)
Neutralizing Agent:SLAKED LIME, SODIUM BICARBONITE, CRUSHED LIMESTONE.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR CONCENTRATIONS FOUND IN WORKPLACE. FOR FURTHER INFORMATION SEE
ORIGINAL MSDS OR REFER TO CFR 1910.134.
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION SYSTEM TO MEET PUBLISHED
EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOGG & FULL LNGTH FCSHLD
Other Protective Equipment:IMPERVIOUS CLOTHING AND EQUIPMENT. EYE WASH
FOUNTAIN & QUICK DRENCH SHOWER.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN.
Supplemental Safety and Health
FIRE FIGHT PROC:CONTR EXPOSED TO FLAMES W/WATER FROM SIDE UNTIL WELL
AFTER FIRE IS OUT. KEEP AWAY FROM STORAGE TANK ENDS. KEEP
UPWIND.USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . CNDTN TO AVOI
D:SPACES. RUNOFF TO SEWER MAY CREATE FIRE/EXPLOS HAZ. EFTS OF
OVEREXPOS:FOLLOWED BY VOMIT/DIARR OF DARK PRECIP (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:131F,55C
Melt/Freeze Pt:M.P/F.P Text:34.0F,1.1C
Vapor Density:2.7
Spec Gravity:1.98
Solubility in Water:REACTS VIOLENTLY
Appearance and Odor:HEAVY, FUMING, YELLOW LIQUID WITH SHARP,
PENETRATING ODOR.

Stability

Stability Indicator/Materials to Avoid:NO
MAY REACT VIOLENTLY W/WATER PROD FLAMM HYDROGEN GAS. OLEUM IS CORR TO
METAL. FOR OTHER MATL TO AVOID SEE ORIGINAL MSDS.
Stability Condition to Avoid:MAY IGNITE OTHER COMBUST MATLS. VIOLENT
REACTION W/H*2O. FLAMM, POISONOUS GASES MAY ACCUM IN CONFINED
(SUPDAT)
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
TOXIC SO*X.

Disposal

Waste Disposal Methods:NEUTRALIZE TO PH-7. DISPOSE OF IN ACCORDANCE
WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.